Part L 2010 came into force on the 1st October 2010, and is satisfied with the scientific method of SAP 2009. The following limiting fabric rules are mandatory for all new build domestic structures and must be adhered to by all developers, architects and energy assessors.

Limiting U values
These values show the upper limit of what is allowable in new build domestic structures. In order to pass SAP however, these values should be surpassed significantly.

Part L 2010

Element U value
Wall 0.3
Party wall 0.2
Floor 0.25
Roof 0.2
Openings 2
Air permeability 10 (m3/hm2)

The recommendations by the same document to pass a SAP assessment are listed below. Care should be taken not to follow this recommendation blindly however as all dwellings will differ. Further guidelines on SAP 2009 solutions have also been listed below - all of which differ slightly to meet the energy model used at the time.

Part L 2010

Element Part L recommendation
Wall 0.20
Party wall 0.2
Floor 0.2
Roof 0.13
Window 1.5
Door 1.5
Thermal bridging Y = 0.04
Ventilation rate 5 (m3/hm2)
Mechanical ventilation

-

Heating -
Solar hot water -

National Energy Services

Element NES recommendation
Wall 0.21
Party wall 0.0
Floor 0.16
Roof 0.12
Window 1.5
Door 1
Thermal bridging Y = 0.04
Ventilation rate 3 (m3/hm2)
Mechanical ventilation

Specific fan power 1 w/l/s
Exchanger efficiency 85%

Heating Gas
Efficiency 90%
Load or weather compensator
Solar hot water None

The Energy Saving Trust

Element Energy Saving Trust recommendation
Wall 0.25
Party wall 0.0
Floor 0.2
Roof 0.13
Window 1.5
Door 1
Thermal bridging Y = 0.04
Ventilation rate 3 (m3/hm2)
Mechanical ventilation

Specific fan power 1 w/l/s
Exchanger efficiency 85%

Heating Gas
Efficiency 90%
Load or weather compensator
Solar hot water None